Difference between revisions of "Microware Radar Sensor"

From ElectroDragon
Jump to navigation Jump to search
 
Line 16: Line 16:
 
* storage temperature -40~100
 
* storage temperature -40~100
 
=== Adjustment ===
 
=== Adjustment ===
 +
[[File:Rcwl 01.png|thumbnail]]
 
* C-TM: repeat trigger time, default 2S, add capacitor can increase repeat time. The method is checking 9196 IC pin 3 frequency, trigger time T = (1/f) * 32768
 
* C-TM: repeat trigger time, default 2S, add capacitor can increase repeat time. The method is checking 9196 IC pin 3 frequency, trigger time T = (1/f) * 32768
 
* R-GN: detect distance, connector resistor, distanct get short. default 7M. for 1M resistor, detect about 5M.
 
* R-GN: detect distance, connector resistor, distanct get short. default 7M. for 1M resistor, detect about 5M.
Line 25: Line 26:
 
* sensor front is main sensing area, back side sensing capability is less better
 
* sensor front is main sensing area, back side sensing capability is less better
 
* The sensor can not be implement on same area in the same time, or will have interference. Each should have at least 1 meter gap.
 
* The sensor can not be implement on same area in the same time, or will have interference. Each should have at least 1 meter gap.
 +
=== Schematic and dimension ===
 +
<gallery>
 +
File:Rcwl_02.jpg | sch
 +
File:Rcwl_03.jpg | dimension
 +
</gallery>
 
[[cateogyr: Promixity]]
 
[[cateogyr: Promixity]]

Latest revision as of 13:34, 6 December 2017

RCWL

Pin Definition

  • 3.3V - LDO 3.3V output
  • GND - ground
  • OUT - outout signal, detect when object move on front
  • VIN - power supply in 4-28V
  • CDS - enable the IC, when lower than 0.7V, output keep on low TTL signal.

Features

  • Voltage 4-28V
  • Current 3mA
  • Detect distance 5-9M
  • Transmit power 20mW
  • Output drive capability 100mA
  • Output signal 0 or 3.3V
  • working temperature -20~80
  • storage temperature -40~100

Adjustment

Rcwl 01.png
  • C-TM: repeat trigger time, default 2S, add capacitor can increase repeat time. The method is checking 9196 IC pin 3 frequency, trigger time T = (1/f) * 32768
  • R-GN: detect distance, connector resistor, distanct get short. default 7M. for 1M resistor, detect about 5M.
  • R-CDS: internal VCC connect between IC pin CDS and R-CDS pin, via 1M internal resistor. CDS connect photocell, can close sensor on night. You can set R-CDS value by the needs of ambient light.

Use note

  • Should have no any metal on front ot sensing area
  • Should keep at least 1CM space free
  • sensor and installation better keep parallel.
  • sensor front is main sensing area, back side sensing capability is less better
  • The sensor can not be implement on same area in the same time, or will have interference. Each should have at least 1 meter gap.

Schematic and dimension

cateogyr: Promixity